-40%
Altronix AL400ULACM Access Power Controller w/ Power Supply/Charger
$ 126.71
- Description
- Size Guide
Description
Designer EntrywayWelcome to Designer Entryway.
HAVE A QUESTION? -
Click to find out more
Feedback
Add to Favorites
Join Mailing List
CATEGORIES
Home
Home & Garden
Consumer Electronics
Business & Industrial
Computers/Tablets & Networking
More
Musical Instruments & Gear
eBay Motors
Cell Phones & Accessories
Cameras & Photo
Sporting Goods
Everything Else
Quick Delivery On All Items
100% Satisfaction Guaranteed
Money Back Guarantee
Product information
Altronix AL400ULACM Access Power Controller w/ Power Supply/Charger
Click on the Image to Enlarge
Description
AL400ULACM
Access Power Controller w/ Power Supply/Charger, 8 Fused Relay Outputs, 12/24VDC @ 4A, FAI, 115VAC, BC400 Enclosure.
Altronix AL400ULACM converts a 115VAC 60Hz input into eight (8) independently controlled 12VDC or 24VDC Fail-Safe and/or Fail-Secure outputs with a total of 4A @ 12VDC or 3A @ 24VDC continuous supply current. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. This unit will route power to a variety of access control hardware devices including Mag Locks, Electric Strikes, Magnetic Door Holders, etc. The outputs will operate in both Fail-Safe and/or Fail-Secure modes. This unit is designed to be powered by one common power source (factory installed) which will provide power for both the board operation and locking devices, or two (2) totally independent power sources, one (1) providing power for board operation and the other for lock / accessory power. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the eight (8) outputs.
Input
Input 115VAC 60Hz rated @ 3.5A.
Power supply input options:
a) One (1) common power input for ACM8/ACM8CB and lock power (factory installed).
b) Two (2) isolated power inputs - One (1) to power the ACM8/ACM8CB and one (1) for lock accessory power, (external power supply is required). (Current is determined by the power supply connected, not to exceed a maximum of 10A total).
Eight (8) Access Control System trigger inputs.
Input options:
a) Eight (8) normally open (NO) inputs.
b) Eight (8) open collector inputs.
c) Any combination of the above.
Output
12VDC or 24VDC outputs.
12VDC @ 4A supply current or 24VDC @ 3A supply current.
Class 2 Rated power limited outputs.
Eight (8) independently controlled outputs.
Output options:
a) Eight (8) Fail-Safe and/or Fail-Secure power outputs.
b) Eight (8) form "C" 5A rated relay outputs
c) Any combination of the above.
Eight (8) auxiliary power outputs (unswitched)
Output ratings:
Fuses are rated @ 3.5A.
Filtered and electronically regulated outputs (built-in power supply).
ACM8 board main fuse is rated at 10A.
Supervision
AC fail supervision (form "C" contacts). Notification trigger is selectable for 30 seconds (factory set) or 6 hours.
Low battery and battery presence supervision (form "C" contact).
Features
Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the eight (8) outputs.
Fire Alarm disconnect input options:
a) Normally open (NO) or normally closed (NC) dry contact input.
b) Polarity reversal input from FACP signaling circuit.
Alarm output relay indicates that FACP input is triggered (form "C" contact rated @ 1A 28VDC not evaluated by UL).
Short circuit and thermal overload protection.
Visual Indicators
Red LEDs indicate outputs are triggered (relays energized).
Green LED indicates FACP disconnect is triggered.
AC input and DC output LED indicators.
Battery Backup
Built-in charger for sealed lead acid or gel type batteries.
Automatic switch over to stand-by battery when AC fails.
Zero voltage drop when unit switches over to battery backup (AC failure condition).
Battery fail and battery presence supervision (form "C" contact).
Temperature
Operating: 0ºC to 49ºC (32ºF to 120ºF).
Storage: - 20ºC to 70ºC ( - 4ºF to 158ºF).
Relative Humidity 85% +/- 5%.
BTU/Hr. (approx.):
12VDC: 25 BTU/Hr.
24VDC: 37 BTU/Hr.
Payment
We accept Paypal as payment method.
Returns
Returns Accepted, Buyer, 30 Days, eBay Return Policy for Exchange or Money Back. All Products has to be in Original Packaging, not used, all seals intact and in a perfect condition.
Designer Entryway, LLC. only accept products returns from the returning party within 30 days of date of original purchase by the customer.
All Return Items Must Be returned to the address provided with the RMA document following the description of the specific defect ( i. e, reason for the return). However, failure to submit any item could impact the eligibility for credit. Upon receipt Designer Entryway, LLC. will assess the condition of the product and will determine if a defect exist in the material/product and will be result for final judgment to determine the final credit.
All Electronic items are to be inspected, in working conditions also they are subject to be inspected for matching Serial numbers from our records.
Contact us
To contact our Customer Service Team, simply click
Send Message
and our Customer Service team will be happy to assist.
We accept Paypal as payment method.
Returns Accepted, Buyer, 30 Days, eBay Return Policy for Exchange or Money Back. All Products has to be in Original Packaging, not used, all seals intact and in a perfect condition.
Designer Entryway, LLC. only accept products returns from the returning party within 30 days of date of original purchase by the customer.
All Return Items Must Be returned to the address provided with the RMA document following the description of the specific defect ( i. e, reason for the return). However, failure to submit any item could impact the eligibility for credit. Upon receipt Designer Entryway, LLC. will assess the condition of the product and will determine if a defect exist in the material/product and will be result for final judgment to determine the final credit.
All Electronic items are to be inspected, in working conditions also they are subject to be inspected for matching Serial numbers from our records.
To contact our Customer Service Team, simply click
Send Message
and our Customer Service team will be happy to assist.
Join Our Exclusive Newsletter For Up To Date News, Special Offers And New Arrivals
Sign up Now
Quick Links
Feedback
Add to Favorites
Contact us
Get in touch with us
Designer Entryway LLC
Kissimmee, Florida
Postal Code 34745
United States
Payment info
Copyright 2019
Designer Entryway LLC.
All Rights Reserved
Listing and template services provided by inkFrog